Improving Lives Through Science

Login | Register

CO₂ Incubators

ProductsCO₂ Incubator › CO₂ Incubators

Must-have features to consider:

  • Fast CO₂, temperature, and humidity recovery without overshoot
  • Best uniformity and control among competition
  • VentiFlow™ forced convection accelerates recovery of chamber air to ISO Class 5 Cleanliness after door closing to prevent contamination.
  • Filtered air circulates across the humidity pan to accelerate the humidifying process.
  • Air flows gently around culture plates, causing no disturbance to cell culture.
  • Blower automatically stops when the door is opened, to minimize mixing of chamber and room air.
  • Comprehensive user-configurable alarms for all the parameters.
  • CelAlert™ alarm system reminds the user to replace CO₂ tank and ULPA filter.
  • Intelligent data and event logger records all incubator parameters for on-screen recall.
  • 2 MB built-in flash memory guarantees long term storage of data.
  • Diagnostic interface and online quick help provide comprehensive solutions to frequently encountered problems.
  • Ductwork, plenums, and shelves are removable without tools.


90˚C MOIST HEAT DECONTAMINATIONe

CO₂ incubator with 90°C MOIST HEAT DECONTAMINATION cycle has been proven in deactivating normally resistant fungi, bacterial spores and vegetative cells by the Health Protection Agency (HPA) in UK. Chamber is cool and dry at the end of full 15-hr decontamination cycle. No further wipe down is needed.

180˚C HIGH HEAT STERILIZATION

180°C HIGH HEAT STERILIZATION conforms to the International Standards for dry heat sterilization and proven to effectively deactivate normally-resistant fungi, bacterial spore and vegetative cells. Nontoxic and noncorrosive sterilization that completes within 12 hours leaving the chamber cool and dry at the end of the cycle.

CelMate® CO₂ Incubator CLM-_B-_
CelMate® CO₂ Incubator- CO₂ Control

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-Cu-UV
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, Copper Chamber, UV Lamp

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • Copper Chamber
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-HITEMP
CelCulture® CO₂ Incubator- with High Temperature CO₂ Sensor

Specifications:

  • High-Temparature Infrared (IR) CO₂ Sensor
  • FDA-listed, Class II, 510k exempt medical device
  • Better uniformity and heating system
  • Ventiflow™ Forced Convection
  • SteriSafe™ ULPA Filtration System
  • HPA Validated 90°C Moist Heat Decontamination
  • ISOCIDE™ Antimicrobial Powder Coating
  • Gas Inlet Filter
CelCulture® CO₂ Incubator with High-Heat Sterilization CCL-_T-_-NF-HHS
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, No ULPA Filter, High Heat Sterilization

Specifications:

  • Direct heat and air jacket
  • Heat-resistant Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • 180 ˚C High-heat sterilization
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator with High-Heat Sterilization CCL-_B-_-NF-HHS
CelCulture® CO₂ Incubator -CO₂ Control, No ULPA Filter, High Heat Sterilization

Specifications:

  • Direct heat and air jacket
  • Heat-resistant Infrared (IR) CO₂  Sensor
  • 180 ˚C High-heat sterilization
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator with High-Heat Sterilization CCL-_T-_-HHS
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, High Heat Sterilization

Specifications:

  • Direct heat and air jacket
  • Heat-resistant Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • 180 ˚C High-heat sterilization
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator with High-Heat Sterilization CCL-_B-_-HHS
CelCulture® CO₂ Incubator - CO₂ Control, High Heat Sterilization

Specifications:

  • Direct heat and air jacket
  • Heat-resistant Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • 180 ˚C High-heat sterilization
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-UV-SS
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, UV Lamp, Stainless Steel Exterior

Specifications:

  • Corrosion-resistant stainless steel exterior surface
  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-SS
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, Stainless Steel Exterior

Specifications:

  • Corrosion-resistant stainless steel exterior surface
  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-UV-SS
CelCulture® CO₂ Incubator - CO₂ Control, UV Lamp, Stainless Steel Exterior

Specifications:

  • Corrosion-resistant stainless steel exterior surface
  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-SS
CelCulture® CO₂ Incubator - CO₂ Control, Stainless Steel Exterior

Specifications:

  • Corrosion-resistant stainless steel exterior surface
  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-P-UV
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, Peltier System, UV Lamp

Specifications:

  • Peltier heating/cooling technology
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-P-UV
CelCulture® CO₂ Incubator - CO₂ Control, Peltier System, UV Lamp

Specifications:

  • Peltier heating/cooling technology
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-P
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, Peltier System

Specifications:

  • Peltier heating/cooling technology
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-P
CelCulture® CO₂ Incubator - CO₂ Control, Peltier System

Specifications:

  • Peltier heating/cooling technology
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-Cu-UV
CelCulture® CO₂ Incubator - CO₂ Control, Copper Chamber, UV Lamp

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Copper Chamber
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelMate® CO₂ Incubator CLM-_B-_-UV
CelMate® CO₂ Incubator- CO₂ Control, UV Lamp

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO2 Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90°C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-Cu
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, Copper Chamber

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • Copper Chamber
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-Cu
CelCulture® CO₂ Incubator - CO₂ Control, Copper Chamber

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Copper Chamber
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-UV-FD
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, UV Lamp, Flat Door

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Flat Door
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-NF-FD
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, No ULPA Filter, Flat Door

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • Flat Door
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-FD
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, Flat Door

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Flat Door
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-UV-FD
CelCulture® CO₂ Incubator - CO₂ Contro, UV lamp, Flat Door

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Flat Door
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-NF-FD
CelCulture® CO₂ Incubator - CO₂ Control, No ULPA Filter, Flat Door

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Flat Door
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-FD
CelCulture® CO₂ Incubator - CO₂ Control, Flat Door

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Flat Door
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-UV
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, UV lamp

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-UV
CelCulture® CO₂ Incubator - CO₂ Control, UV lamp

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • UV Lamp
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-NF
CelCulture® CO₂ Incubator - CO₂ & O₂ Control, No ULPA Filter

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_T-_
CelCulture® CO₂ Incubator - CO₂ & O₂ Control

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Suppressed Oxygen Control
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_B-_-NF
CelCulture® CO₂ Incubator - CO₂ Control, No ULPA Filter

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 170 L and 240 L
CelCulture® CO₂ Incubator CCL-_B-_
CelCulture® CO₂ Incubator- CO₂ Control

Specifications:

  • Direct heat and air jacket
  • Infrared (IR) CO₂  Sensor
  • ULPA Filter
  • Ventiflow™ Forced Convection
  • Validated 90˚C moist heat decontamination cycle
  • FDA-listed, Class II, 510k exempt medical device
  • Available volume: 50 L, 170 L, and 240 L
CelCulture® CO₂ Incubator CCL-_T-_-HITEMP
CelCulture® CO₂ Incubator- with High Temperature CO₂ Sensor

Specifications:

  • High-Temparature Infrared (IR) CO₂ Sensor
  • FDA-listed, Class II, 510k exempt medical device
  • Better uniformity and heating system
  • Ventiflow™ Forced Convection
  • SteriSafe™ ULPA Filtration System
  • HPA Validated 90°C Moist Heat Decontamination
  • ISOCIDE™ Antimicrobial Powder Coating
  • Gas Inlet Filter

Frequently Asked Questions