Esco PROtect is a truly wireless redundant monitoring system. Operating 24/7, it will send real time local and remote alarms notifications. Esco will help you to PROtect your samples, save you on costs and comply with regulatory requirements in your lab!
Complies to following standards:
Modems, Relays and Alarm System | ||
Item Codes | Description | Features/Specifications |
1081050 | ESCO PROtect UN-1 -868 Mhz band |
|
1081051 | ESCO PROtect UN-1 -902 Mhz band | |
1081052 | ESCO PROtect UN-2 -868 Mhz band |
|
1081053 | ESCO PROtect UN-2 -902 Mhz band | |
1081054 | ESCO PROtect DG-1 -868 Mhz band |
|
1081055 | ESCO PROtect DG-1 -902 Mhz band | |
1081058 | ESCO PROtect MD-1 -868 Mhz band |
|
1081059 | ESCO PROtect MD-1 -902 Mhz band | |
1081060 | ESCO PROtect EMD-1 -868 Mhz band |
|
1081061 | ESCO PROtect EMD-1 -902 Mhz band | |
1081062 | ESCO PROtect RL-1 -868 Mhz band |
|
1081063 | ESCO PROtect RL-1 -902 Mhz band | |
1081064 | ESCO PROtect AM-1 -868 Mhz band |
|
1081065 | ESCO PROtect AM-1 -902 Mhz band |
Options and Accessories | ||
Item Codes | Description | Features/Specifications |
1081070 | PROtect Software and Dongle |
|
1081071 | Audible and Visual Alarm Device |
|
1081072 | PT100 Probe |
|
1081073 | Digital Temperature Probe |
|
1081075 | Battery for Recorders |
|
1081076 | ESCO PROtect CO 2 probe |
|
1081078 | Power supply for USB Modem, Ethernet Modem and Alarm System |
|
1081079 | Power Supply for Relay |
|
1081080 | Universal Adaptor Cable for |
|
1081081 | Digital Temperature/Humidity Probe |
|
1081066
|
PROtect Test-1 868 MHz |
• Use as a recorder to test connection between modem and recorder with actual percentage signal |
1081067
|
PROtect Test-1 902 MHz |
|
1081068
|
PROtect Modem Test-1 868 MH |
• Use as a modem to test connection between modem and recorder with actual percentage signal |
1081069
|
PROtect Modem Test-1 902 MHz
|
|
1081070
|
PROtect Software and Dongle |
• Remote visualization of data. • Downloaded database is presented in easy to understand reports or graphs. • PROtect software enables to visualize recorders located on the installation map and to manage your alarm. • Compliant with FDA (CFR 21 part 11) Note: PROtect software and dongle needs to be installed even if one (1) PROtect recorder (UN or DG) is connected to the equipment. |
1081071
|
Audible and Visual Alarm Device |
• Warns if an alarm occurs. • Works with an external power supply. • Connects directly to PROtect Modem or to PROtect Alarm. • Audible and visual Alarm. |
1081072
|
PT100 Probe Class B
|
• Measurement range: -200°C to + 260°C • Type of cable: 3 wires (3m) |
1081288
|
PT100 Probe Class A
|
|
1081289
|
PT100 Probe Class 1/3 DIN
|
|
1081073
|
Digital Temperature Probe |
• Type of probe: Dallas • Measurement range: -40°C to + 80°C (-45°C max) accuracy: ± 0.3°C • Type of cable: flat 3m cable • Embedded memory for gauging parameters storage |
1081075
|
Battery for Recorders
|
• Lithium Battery for 10 pcs
|
1081081
|
Digital Temperature/Humidity Probe
|
Measurement range : -40 +80°C /0 100%HR • Type of probe for T°: Pt 100 Class A • Class A • Accuracy: ±2%HR from 0 to 90%HR ±3%HR from 90 to 100%HR • Power: delivered by the SPYRF recorder |
1081166
|
Digital (Low) Temperature
|
• Type of probe: Low Temp Stainless Steel probe • Type of cable: 3m Teflon Cable • Measurement range from 0°C to -200°C accuracy: ± 0.2°C • Immersion of cable: continuous immersion in water and glycolic solutions and punctual immersion in alcoholic solutions” |
1081080
|
Universal Adaptor Cable for CO2 and DP sensors
|
• (5m) with connector IP67 for PROtect UN and DG.
|
1081262
|
SMS Modem
|
• Warns if any alarm occurs by sending SMS to receiver’s number • Needs a SIM card • Supports multiple receiver’s number • USB Connection |
1081076
|
PROtect CO2 Probe
|
• Measurement range : 0 – 20% • Output : 4-20 mA • Mounting : Wall mounting bracket supplied • Supply: 100-240 VAC |
5072029
|
PROtect Differential Pressure Probe |
• Measurement Range: -100 Pa to +100 Pa • Output: 4 - 20 mA • Supply: 100-240 VAC (include Power Supply 1081263) |
1081078
|
PROtect Test-1 902 MHz
|
• Power Supply for MD-1, EMD-1, AM-1
|
1081079
|
Power Supply for Relay |
• Power supply for RL-1
|
1081167 |
PROtect Door Contact (With Sliding Doors) |
• Use to sense door contact that door is open or close
|
1081168 |
PROtect Door Contact (Non-Sliding Doors) |
• Use to sense door contact that door is open or close
|
5072009
|
PROtect GSM Auto Dialer set |
• Warns if any alarm occurs by call receiver number (auto dialer) • Needs a SIM card • Supports until three (3) receiver numbers • Supply: 100-240 VAC (include Power Supply 1081291) |
PROtect Server:
Computer Architecture: 32 bit and 64 bit
OS: Windows 2000, XP, Vista, Win 7 and Windows 2003-2008 Server
RAM: 3 GB (min)
HD: 250 GB capacity or higher
Video Card: VGA compatible 1280 X 1024 32 bit (minimum)
PROtect Client:
Computer Architecture: 32 bit and 64 bit
OS: Windows 2000, XP, Vista, Win 7 and Windows 2003-2008 Server
RAM: 2 GB (minimum)
HD: 1 GB capacity or higher
Video Card: VGA compatible 1280 X 1024 32 bit (minimum)
Modems, Relays and Alarm System | ||
Item Codes | Description | Features/Specifications |
1081050 | ESCO PROtect UN-1 -868 Mhz band |
|
1081051 | ESCO PROtect UN-1 -902 Mhz band | |
1081052 | ESCO PROtect UN-2 -868 Mhz band |
|
1081053 | ESCO PROtect UN-2 -902 Mhz band | |
1081054 | ESCO PROtect DG-1 -868 Mhz band |
|
1081055 | ESCO PROtect DG-1 -902 Mhz band | |
1081058 | ESCO PROtect MD-1 -868 Mhz band |
|
1081059 | ESCO PROtect MD-1 -902 Mhz band | |
1081060 | ESCO PROtect EMD-1 -868 Mhz band |
|
1081061 | ESCO PROtect EMD-1 -902 Mhz band | |
1081062 | ESCO PROtect RL-1 -868 Mhz band |
|
1081063 | ESCO PROtect RL-1 -902 Mhz band | |
1081064 | ESCO PROtect AM-1 -868 Mhz band |
|
1081065 | ESCO PROtect AM-1 -902 Mhz band |
Options and Accessories | ||
Item Codes | Description | Features/Specifications |
1081070 | PROtect Software and Dongle |
|
1081071 | Audible and Visual Alarm Device |
|
1081072 | PT100 Probe |
|
1081073 | Digital Temperature Probe |
|
1081075 | Battery for Recorders |
|
1081076 | ESCO PROtect CO 2 probe |
|
1081078 | Power supply for USB Modem, Ethernet Modem and Alarm System |
|
1081079 | Power Supply for Relay |
|
1081080 | Universal Adaptor Cable for |
|
1081081 | Digital Temperature/Humidity Probe |
|
1081066
|
PROtect Test-1 868 MHz |
• Use as a recorder to test connection between modem and recorder with actual percentage signal |
1081067
|
PROtect Test-1 902 MHz |
|
1081068
|
PROtect Modem Test-1 868 MH |
• Use as a modem to test connection between modem and recorder with actual percentage signal |
1081069
|
PROtect Modem Test-1 902 MHz
|
|
1081070
|
PROtect Software and Dongle |
• Remote visualization of data. • Downloaded database is presented in easy to understand reports or graphs. • PROtect software enables to visualize recorders located on the installation map and to manage your alarm. • Compliant with FDA (CFR 21 part 11) Note: PROtect software and dongle needs to be installed even if one (1) PROtect recorder (UN or DG) is connected to the equipment. |
1081071
|
Audible and Visual Alarm Device |
• Warns if an alarm occurs. • Works with an external power supply. • Connects directly to PROtect Modem or to PROtect Alarm. • Audible and visual Alarm. |
1081072
|
PT100 Probe Class B
|
• Measurement range: -200°C to + 260°C • Type of cable: 3 wires (3m) |
1081288
|
PT100 Probe Class A
|
|
1081289
|
PT100 Probe Class 1/3 DIN
|
|
1081073
|
Digital Temperature Probe |
• Type of probe: Dallas • Measurement range: -40°C to + 80°C (-45°C max) accuracy: ± 0.3°C • Type of cable: flat 3m cable • Embedded memory for gauging parameters storage |
1081075
|
Battery for Recorders
|
• Lithium Battery for 10 pcs
|
1081081
|
Digital Temperature/Humidity Probe
|
Measurement range : -40 +80°C /0 100%HR • Type of probe for T°: Pt 100 Class A • Class A • Accuracy: ±2%HR from 0 to 90%HR ±3%HR from 90 to 100%HR • Power: delivered by the SPYRF recorder |
1081166
|
Digital (Low) Temperature
|
• Type of probe: Low Temp Stainless Steel probe • Type of cable: 3m Teflon Cable • Measurement range from 0°C to -200°C accuracy: ± 0.2°C • Immersion of cable: continuous immersion in water and glycolic solutions and punctual immersion in alcoholic solutions” |
1081080
|
Universal Adaptor Cable for CO2 and DP sensors
|
• (5m) with connector IP67 for PROtect UN and DG.
|
1081262
|
SMS Modem
|
• Warns if any alarm occurs by sending SMS to receiver’s number • Needs a SIM card • Supports multiple receiver’s number • USB Connection |
1081076
|
PROtect CO2 Probe
|
• Measurement range : 0 – 20% • Output : 4-20 mA • Mounting : Wall mounting bracket supplied • Supply: 100-240 VAC |
5072029
|
PROtect Differential Pressure Probe |
• Measurement Range: -100 Pa to +100 Pa • Output: 4 - 20 mA • Supply: 100-240 VAC (include Power Supply 1081263) |
1081078
|
PROtect Test-1 902 MHz
|
• Power Supply for MD-1, EMD-1, AM-1
|
1081079
|
Power Supply for Relay |
• Power supply for RL-1
|
1081167 |
PROtect Door Contact (With Sliding Doors) |
• Use to sense door contact that door is open or close
|
1081168 |
PROtect Door Contact (Non-Sliding Doors) |
• Use to sense door contact that door is open or close
|
5072009
|
PROtect GSM Auto Dialer set |
• Warns if any alarm occurs by call receiver number (auto dialer) • Needs a SIM card • Supports until three (3) receiver numbers • Supply: 100-240 VAC (include Power Supply 1081291) |
PROtect Server:
Computer Architecture: 32 bit and 64 bit
OS: Windows 2000, XP, Vista, Win 7 and Windows 2003-2008 Server
RAM: 3 GB (min)
HD: 250 GB capacity or higher
Video Card: VGA compatible 1280 X 1024 32 bit (minimum)
PROtect Client:
Computer Architecture: 32 bit and 64 bit
OS: Windows 2000, XP, Vista, Win 7 and Windows 2003-2008 Server
RAM: 2 GB (minimum)
HD: 1 GB capacity or higher
Video Card: VGA compatible 1280 X 1024 32 bit (minimum)
Esco Micro Pte. Ltd.
21 Changi South Street 1 Singapore 486777
+65 65420833 | +65 65426920