Esco » Ductless Fume Hoods » Products: Ascent® Max Ductless Fume Hood - With Secondary Back Up Carbon Filter ADC (C-Series)

Ascent® Max Ductless Fume Hood - With Secondary Back Up Carbon Filter ADC (C-Series)

Max Ductless Fume Hood - With Secondary Back Up Carbon Filter ADC (C-Series) Picture

The Ascent Max Ductless Fume Hood with secondary back up carbon exhaust filter offers a higher filtration efficiency against toxic fumes.


Key Benefits:
  • Certified to AFNOR NF X 15-203, BS7258, BS7989, ASHRAE110, EN14175-3
  • Large working area
  • Robust steel carcass construction
  • Isocide powder coating
  • Excellent aesthetics
  • Elegant and smooth sliding sash window
  • State of the art Sentinel airflow monitor and alarm system

ISOCIDE

  • Grade 304 stainless steel work surface that will never rust, chip, or generate particles.
  • Lip at the front edge of the work surface ensures that any spillage is contained within the workzone.
  • A fully configurable Sentinel™ microprocessor control with audible and visual alarms for unsafe conditions.
  • Built-in 5000k warm white fluorescent lighting.
  • Front service panel opens up easily for immediate access for all maintenance functions.
  • Small Filter ID window to easily identify the type of filter being used.
  • Powder-coated, panel-mounted single electrical outlet provision.
  • Isocide™ antimicrobial coated structure eliminates 99.9% of bacterial presence on external surfaces within 24 hours.
  • All cabinet service and filter replacement can be carried out from the front, allowing the cabinet to be placed against walls in the laboratory to save space.
  • Electronic module behind the hinged front panel for easy access during troubleshooting and certification.
  • Retrofit Kit™ service fixture for air/water/vacuum/gas outlets.
  • Retrofit Kit™ Polypropylene drip-cup sink and epoxy powder-coated swan neck faucet.
  • Exhaust collar for added operator safety.
  • VOC sensor to monitor the chemical concentration within the cabinet workzone.
  • Secondary back-up activated carbon filter (complies with the requirements of ANSI/AIHA Z9.5-2003).
  • Base cabinet and support stand accesories.
  • Over 7 different Nanocarb™ carbon filter types, choose from: volatile organic compound, acid, mercury, sulphur, halogen, aldehyde or ammonia.
Model No. External
Dimensions (mm)
Internal
Dimensions (mm)
Airflow
Velocity (Inflow)
Airflow
Velocity (Downflow)
Electrical
ADC-3C1
1035 x 736 x 1460
965 x 642 x 780
0.40(m/s) /
80(fpm)
-
220-240V,AC, 50Hz,1ø
ADC-3C2 110-120V,AC, 60Hz,1ø
ADC-3C3 220-240V,AC, 60Hz,1ø
ADC-4C1
1340 x 736 x 1460
1268 x 642 x 780
0.40(m/s) /
80(fpm)
-
220-240V,AC, 50Hz,1ø
ADC-4C2 110-120V,AC, 60Hz,1ø
ADC-4C3 220-240V,AC, 60Hz,1ø
ADC-5C1
1645 x 736 x 1460
1575 x 642 x 780
0.40(m/s) /
80(fpm)
-
220-240V,AC, 50Hz,1ø
ADC-5C2 110-120V,AC, 60Hz,1ø
ADC-5C3 220-240V,AC, 60Hz,1ø
ADC-6C1
1950 x 736 x 1460
1880 x 642 x 780
0.40(m/s) /
80(fpm)
-
220-240V,AC, 50Hz,1ø
ADC-6C2 110-120V,AC, 60Hz,1ø
ADC-6C3 220-240V,AC, 60Hz,1ø
Support Stands
  • Support Stand with Caster Wheels (SPC)
    • Available in two standard heights: 711mm (28") or 860mm (34”)
    • Durable polyurethane caster wheels with 360 degree horizontal rotation
    • Brake system on front wheels
    • Maximum weight supported: 600 kg (1323 lbs)
  • Support Stand with Leveling Feet (SAL)
    • Available in two standard sizes: 737 mm (29”) or 838 mm (33”), ±38.1 mm (1.5")
    • Maximum weight supported: 500 kg (1100 lbs)
  • Telescoping Support Stand (STL)
    • Adjustable height range: 660mm to 960mm (26” to 37.8”)
    • Adjustable in 25.4 mm (1") increments
    • Maximum weight supported: 600 kg (1323 lbs)
  • Motorized Hydraulic Adjustable Support Stand (SPM)
    • Adjustable height range: 711 mm to 863 mm (28" to 34")
    • With leveling feet or casters
    • Maximum weight supported: 500 kg (1100 lbs)
Electrical Outlets and Utility Fittings
  • Electrical Outlets
    • Powder-coated, panel-mounted single electrical outlet.
    • Available in all international socket outlet types. Specify when ordering.
    • May be field installed.
  • VOC Sensor
    • Optional VOC Sensor may be installed to monitor the chemical concentration at the hood exhaust.
    • The microprocessor control will activate audible / visual alarms if high concentrations of chemical vapors are detected.
    • Factory installed; specify when ordering
  • Factory-Installed Service Fixtures
    • Polypropylene drip-cup sink.
    • Epoxy coated swan-neck faucet manufactured according to BS 2874, DIN 12898, DIN 12919 and DIN 3537.
    • Factory installed; specify when ordering
  • Retrofit Kit™ Service Fixtures
    • Service fixtures for air / water / vacuum / gas.
    • Manufactured according to DIN 12898, DIN 12919 and DIN 3537.
    • May be field installed.
Other Options and Accesories
  • Base Cabinet with Caster Wheels (BCC)
  • Maximizes storage space in the laboratory; convenient for solvents, acids and other laboratory chemicals.
  • Includes an adjustable white powder-coated steel shelf
  • Industrial-grade support structure constructed of electro-galvanized steel and abrasion resistant ovenbaked powder-coated finish
  • Durable polyurethane caster wheels with 360 degree horizontal rotation
  • Brake system on front wheels
  • Maximum weight supported: 600kg (1323 lbs)
FiltraCheck™ Online Form Airflow

  • Ductless fume cabinets provide operator and environment protection from toxic vapors, gases and fumes.
  • The inflow moves from the ambient environment into the work zone through the cabinet front opening, with an average velocity of 0.5 m/s or 100 fpm. Additional inflow air taken through the AutoPurge perforations at the back of the work zone prevents fume accumulation for better operator protection. Negative pressure is created in the cabinet's work zone, with no outflow created to compromise operator safety.
  • The inflow flushes the entire work zone of the cabinet; within the main chamber of the cabinet, negative pressure (relative to the ambient environment) is maintained so that no chemical fumes or vapors escape the work zone.
  • Air is taken through a pre-filter and an activated carbon filter mounted in the interior. The pre-filter is built-in with the activated carbon filter, prolonging carbon filter life by removing large particulates before the they enter the carbon filter. The carbon filter removes all fumes from the exhaust air stream; filtered clean air is exhausted directly back to the room from the top of the cabinet.
  • The ductless fume cabinet can be remotely exhausted to the external atmosphere via a non-airtight thimble ducting system (optional), providing additional protection for the operator from volatile toxic chemicals used in high amounts, which normally would not be completely  removed by the exhaust filter.

STANDARDS COMPLIANCE CHEMICAL FUME CONTAINMENTFILTER EFFICIENCYELECTRICAL SAFETY
ANSI/ASHRAE 110-1995, USA
BS 7258,UK
AFNOR NF X 15-203, France
EN14175.3,Europe
BS7989-2001, UK
AFNOR NF X 15-211, France
UL-C-61010-1,USA
CAN/CSA-22.2,No.61010-1
EN-61010-1,Europe
IEC61010-1,Worldwide